Abstract

In order to study the effect of cathodic protection potential on coating stripping, the protection potential was improved , the on potential and instant-off potential data of buried pipline were collected, the distance after coating stripping was measured. The results show that when the instant-off potential is-1 . 2 V, the on potential and instant-off potential decrease with the increase of distance, but at some damage points this rule can not be met to the absolute value of the on potential and instantoff potential . The stripping distance for different anticorrosive coating pipelines is not the same.

Key words

buried steel pipeline; coating; cathodic protection; cathodic delamination

Cite this article

Download Citations
ZHENG Xing-wen, ZHANG Ting, LIU Zheng, GONG Min, XIONG Juan, LIN Xiu-zhou, LU Li-juan. Effect of Polarization Potentials on Coating Stripping of Buried Steel Pipelines[J]. Surface Technology. 2013, 42(1): 32-34