JIA Jing-huan,LIU Zhi-yong,DU Cui-wei,LI Xiao-gang.Stress Corrosion Behavior of 316L Stainless Steel in High-pH Alkaline Sulphide Solution[J],44(3):36-40,56
Stress Corrosion Behavior of 316L Stainless Steel in High-pH Alkaline Sulphide Solution
Received:November 14, 2014  Revised:March 20, 2015
View Full Text  View/Add Comment  Download reader
DOI:10.16490/j.cnki.issn.1001-3660.2015.03.006
KeyWord:316L stainless steel  alkaline solution  sulphide  stress corrosion
           
AuthorInstitution
JIA Jing-huan 1. Corrosion and Protection Center, University of Science and Technology Beijing, Beijing , China;2. Key Laboratory of Corrosion and Protection of Ministry of Education, Beijing , China
LIU Zhi-yong 1. Corrosion and Protection Center, University of Science and Technology Beijing, Beijing , China;2. Key Laboratory of Corrosion and Protection of Ministry of Education, Beijing , China
DU Cui-wei 1. Corrosion and Protection Center, University of Science and Technology Beijing, Beijing , China;2. Key Laboratory of Corrosion and Protection of Ministry of Education, Beijing , China
LI Xiao-gang 1. Corrosion and Protection Center, University of Science and Technology Beijing, Beijing , China;2. Key Laboratory of Corrosion and Protection of Ministry of Education, Beijing , China
Hits:
Download times:
Abstract:
      Objective To study the stress corrosion cracking (SCC) behavior of 316L stainless steel in alkaline sulphide solution, and to provide reference for its applicability in alkaline environment. Methods Potentiodynamic polarization, electrochemical impedance spectrums (EIS), slow strain rate test(SSRT), U type bending immersion test and superficial analysis technique using scanning electron microscope (SEM) were applied. Results 316L stainless steel had relatively low SCC susceptibility in alkaline sulphide solution, and the main corrosion mechanism was anodic dissolution (AD). The SCC susceptibility decreased with the increase of pH value. Conclusion Although 316L stainless steel showed features of stress corrosion in alkaline NaCl/ Na2S solution, the SCC sensitivity was low, so it was suitable for the simulated alkaline solution in the experiment.
Close