JI Hong,LI Yong-feng.The Application of Prior Nitric Acid Treatment in the Assessment of Sealing Quality of Anodic Oxidation Coatings[J],(6):125-127
The Application of Prior Nitric Acid Treatment in the Assessment of Sealing Quality of Anodic Oxidation Coatings
Received:July 07, 2012  Revised:December 20, 2012
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:prior nitric acid treatment  sealing quality  alloy anodic oxide coatings  the phosphoric/ chromic acid immersion method
     
AuthorInstitution
JI Hong Center for Analytical Technology, General Research Institute for Non-ferrous Metals, Beijing , China
LI Yong-feng Center for Analytical Technology, General Research Institute for Non-ferrous Metals, Beijing , China
Hits:
Download times:
Abstract:
      Sealing quality directly affects the service life of the anode anodic oxidation coatings. For the anodic oxidation coatings intended for exterior buildings, the phosphoric/ chromic acid immersion with prior nitric acid treatment test method is specified as arbitration method in european standard. The effect of the prior nitric acid treatment on sealing quality test was studied. The results show that the prior nitric acid treatment has the action of dissolution and enlargement. The introduce of the prior nitric acid treatment in sealing quality test provides a more strict sealing quality test method, makes the sealing quality discrimination becoming more sensitive.