YU Fu-jin,HUA Yun-song,ZHANG Ke_hua,DING Jin-fu.Contrast Experimental Study on Residual Stress Measurement of Roller[J],37(6):44-46,56
Contrast Experimental Study on Residual Stress Measurement of Roller
Received:August 18, 2008  Revised:December 10, 2008
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:Residual stress  Roller  Test method  Critical refracted longitudinal wave
           
AuthorInstitution
YU Fu-jin Institute of Machinery Equipment and Measurement & Control Technology, Zhejiang Normal University, Jinhua , China
HUA Yun-song University of Shanghai for Science and Technology, Shanghai , China
ZHANG Ke_hua 1. Institute of Machinery Equipment and Measurement & Control Technology, Zhejiang Normal University, Jinhua , China;2. Zhejiang University of Technology, Hangzhou , China
DING Jin-fu Institute of Machinery Equipment and Measurement & Control Technology, Zhejiang Normal University, Jinhua , China
Hits:
Download times:
Abstract:
      The residual stress measurement of roller is very difficult because that the roller has gigantic volume, the surface is out of order and especially there are oxide film and microcrack. In order to test the veracity of the method of the critical refracted longitudinal wave measurement (CRLWM) , the CRLWM method, the X radial method and the dead hole method were employed to test the residual stress, and the test result of this three methods was compared to evaluate reliability and validity of CRLWM. The result shows that the result of all of the test method is consentaneous.