乔永莲,沙春鹏,董宇,刘冰.镀镍槽液中镍含量的在线监测系统研究[J].表面技术,2015,44(11):128-133.
QIAO Yong-lian,SHA Chun-peng,DONG Yu,LIU Bing.Concentration of Nickel in Nickel Plating Bath by on-line Monitoring System[J].Surface Technology,2015,44(11):128-133
镀镍槽液中镍含量的在线监测系统研究
Concentration of Nickel in Nickel Plating Bath by on-line Monitoring System
投稿时间:2015-08-25  修订日期:2015-11-20
DOI:10.16490/j.cnki.issn.1001-3660.2015.11.020
中文关键词:  槽液组成  电化学测量  自动化  在线监测  PLC 技术
英文关键词:bath composition  electrochemical measurement  automation  on-line monitoring  PLC
基金项目:国家科技重大专项课题资助(2013zx04001041)
作者单位
乔永莲 沈阳飞机工业(集团)有限公司 工艺研究部, 沈阳 110850 
沙春鹏 沈阳飞机工业(集团)有限公司 工艺研究部, 沈阳 110850 
董宇 中国人民解放军驻沈阳飞机工业(集团)有限公司 军事代表室, 沈阳 110034 
刘冰 沈阳飞机工业(集团)有限公司 工艺研究部, 沈阳 110850 
AuthorInstitution
QIAO Yong-lian Technology Research Institute, AVIC Shenyang Aircraft Corporation, Shenyang 110850, China 
SHA Chun-peng Technology Research Institute, AVIC Shenyang Aircraft Corporation, Shenyang 110850, China 
DONG Yu PLA Military Representative Office in Shenyang Aircraft Industries(Group)Co. , Ltd. , Shenyang 110034, China 
LIU Bing Technology Research Institute, AVIC Shenyang Aircraft Corporation, Shenyang 110850, China 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 研发一种能够在线监测镀镍槽液中镍离子含量的测试系统,并将此方法推广至镀铬、镉、铜等槽液。 方法 利用计算机 VC++语言编程技术、Modbus 通讯技术、西门子 PLC 技术组成监控系统,通过耐酸碱计量泵和耐酸碱流量计对镀镍槽液取液量进行控制和校正,采用电化学测试方法对待测槽液在线监测,采用 VC++语言编程技术采集电化学测试数据,最终实现对镀镍槽液中镍离子含量的自动监测。结果 采用此自动控制系统测量镀镍槽液中镍离子的质量浓度,其与极化曲线中-1. 0 V(vs. SCE)电位下的极化电流之间的线性拟合方程为:I=0. 002 01+6. 90×10-5ρ。 以 120 g/ L 待测溶液为分析对象,采用此自动检测系统测得镀镍液中 Ni2+质量浓度为115. 5 g/ L,而采用 EDTA 直接滴定分析测得 Ni2+质量浓度为 113. 7 g/ L,测量误差分别为 3. 78% 和 5. 25% 。 结论 该镀镍槽液中镍离子含量的在线监测方法可靠性高,除了对镀镍槽液状态进行监控分析外,还能对镀铬槽液、镀镉槽液等进行监控分析,可适应较恶劣的生产环境。
英文摘要:
      Objective To develop a new method for on-line monitoring of the concentration of nickel ions in nickel plating, and to expand its application to chromeplate, cadmium plating, copper plating and so on. Methods The system was composed by VC++ Language programming, Modbus communication technology and PLC Siemens technology. The amount of nickel plating bath was controlled and revised by meter pump and flowmeter for nickel ion monitoring. The bath solution was automatically monitored by electrochemical testing method and then the results were collected by VC++ Language programming. Thus, the composition of nickel plating bath can be automatically monitored by this excellent and reliable method. Results The relationship between the nickel ions and the polarization current value at -1. 0 V(vs. SCE)was fitted as I=0. 002 01+6. 90×10-5ρ by the system of on-line monitoring of nickel ion concentration. For 120 g / L nickel plating solution, the concentration of the nickel ions was detected as 115. 5 g / L and 113. 7 g / L and the measuring error was 3. 78% and 5. 25% by this on-line monitoring and the EDTA titrimetric analysis, respectively. Conclusion With its high reliability, the system can not only be used to monitor the status of nickel plating bath, but also for the cadmium plating bath and the chromium plating bath. Most importantly, it can be used in harsh environment.